Description
The unique circuitry of the 750 Series II Conductivity Monitor/controllers guarantees accurate and reliable measurements. Drift-free performance is assured by “field-proven” electronics, including automatic DC offer compensation and highly accurate drive voltage. Since temperature compensation is at the heart of accurate water measurement, all Myron L monitors/controllers feature a highly refined and precise TC circuit. This feature perfectly matches the water temperature coefficient as it changes. All models are corrected to 25°C. The temperature compensation may be disabled to conform with USP requirements. Built-in electronic calibration allows for fast quality checks without standard solutions. For maximum system accuracy, standard solutions are recommended. A push-to-test button makes set point checks easy, while the internal alarm set discourages unauthorized adjustments. Standard on all controller models is a heavy-duty 10 amp output relay, operating on either increasing or decreasing reading. Bright green/red LEDs indicate above or below-set point readings. All 750 Series II models feature an IP65/NEMA 4X water-resistant and corrosion-proof rated enclosure. Compact in size at 6″ x 4.8″, they are suitable for panel, bench, or surface mounting.
Features
– 34 Conductivity/TDS ranges 0-1 microsiemens/ppm to 0-200 millisiemens/ppt– Choice of 3-1/2″ digit display or analog meter– Automatic temperature compensation to 25°C– Isolated 0-10 VDC Recorder Output standard– IP65/NEMA 4x water-resistant and corrosion-proof enclosure– Built-in electronic calibration– Single set point/alarm– Adjustable set point hysteresis– Solid state 24 VDC output– 10 amp relay operates on the choice of increasing or decreasing reading– LEDs show “above/below” Alarm/control status– Push-to-test setpoint discourages unauthorized adjustment– Selectable 115/230 VAC– CE certified– Unique easily installed sensor
Specifications – Accuracy: Analog Models: +/- 2% of full scale Digital Models: +/- 1% of full scale- Sensitivity: 0.05% of full scale- Stability: 0.05% of full scale- Repeatability: 0.1% of full scale- Calibration Check: Built-in- Recorder Output: 0-10 VDC @ 5 mA max (linear)- Sensor Input: 1 (3 input options available)- Solid State Output: Powered; 24 VDC unregulated 30mA max.- Power: 115/230VAC, 50/60 Hz 24 VAC or VDC optional-Weight: 2 lbs Applications– Reverse Osmosis – Process Control– Seawater Desalination – Waste Treatment– Food Processing – Plating– Power Plants – Laboratories– Printing – Aquaculture– Agriculture – Environmental Studies– Medical – Boilers (250 psi @ 205°C)– Cooling Towers









