Description
The Solinst LevelVent 6 is a vented version of the popular Levelogger®. The highly-accurate datalogger is designed to record water level and temperature measurements during shallow groundwater and surface water deployments.
The LevelVent 6 logger contains pressure and temperature sensors, a 10-year battery, memory for up to 150,000 data logs, and a hydrophobic filter, housed in a 22 mm x 173 mm (7/8″ x 6.8″) stainless steel enclosure. Its Faraday cage design protects against power surges or electrical spikes caused by lightning.
The LevelVent 6 is programmed and data downloaded using Solinst Levelogger Software and a high-speed Mk3 USB-C PC Interface Cable. It can also be used with the Solinst Levelogger App Interface, Solinst Readout Unit (SRU) and DataGrabber.
All accessories and PC Interface Cable conveniently connect directly to the LevelVent 6 wellhead.
Note: Vented cables sold separately
Features:
- High-speed, reliable communication with a Mk3 USB-C PC Interface Cable
- Gauged pressure sensor for highly-accurate water level measurements: 0.05% FS
- Compact wellhead makes deployment simple using a Solinst 2″ Well Cap Assembly
- Communication cables and accessories connect directly to the wellhead
- Long-lasting battery included in logger
- Built-in hydrophobic filters and desiccants – no need to replace, reduces
maintenance
Applications:
- Ideal for shallow deployment: up to 20 m (65 ft) submergence
- Aquifer characterization: pumping tests, slug tests, etc.
- Stream gauging, lake, reservoir and dam management
- Watershed, drainage basin and recharge monitoring
- Stormwater and runoff monitoring
- Water supply and tank level measurement
- Long-term water level monitoring in wells and surface water
Specifications:
| LevelVent 6 Logger Specifications | |
|---|---|
| Level Sensor: | Piezoresistive Silicon with Hastelloy Sensor |
| Accuracy: | ± 0.05% FS Typical |
| Stability of Readings: | Superior, low noise |
| Resolution: | 0.001% FS to 0.0006% FS |
| Units of Measure: | m, cm, ft., psi, kPa, bar, °C, °F |
| Normalization: | Automatic Temperature Compensation |
| Temp. Comp. Range: | 0° to 50°C |
| Temperature Sensor: | Platinum Resistance Temperature Detector (RTD) |
| Operating Temperature: | -20°C to 80°C |
| Temp. Sensor Accuracy: | ± 0.05°C |
| Temp. Sensor Resolution: | 0.003°C |
| Battery Life Estimate: | 10 Years — based on 1 reading/minute |
| Clock Accuracy (typical): | ± 1 minute/year (-20°C to 80°C) |
| Maximum Readings: | 150,000 sets of readings (dedicated backup memory for latest 20,000 readings) |
| Memory: | Slate and Continuous |
| Communication: | 38.4k baud with Mk3 USB-C PC Interface Cable, 9600 with Solinst USB, SDI-12, MODBUS |
| Size: | 22 mm x 173 mm (7/8″ x 6.8″) |
| Weight: | 190 grams (6.7 oz) |
| Other Wetted Materials: | Delrin®, Viton®, Polyurethane (TPU boot) 316L stainless steel |
| Sampling Modes: | Linear, User-Selectable Schedule with Repeat & Pause Modes, Event, Future Start, Future Stop, Real-Time View |
| Measurement Rates: | 1/8 sec to 99 hrs |
| Barometric Compensation: | Automatic |