Description
The Levelogger® 6 LTC logs water level, temperature, and conductivity. It combines a datalogger, 8-year battery, Hastelloy® pressure sensor, temperature detector, and conductivity sensor within a small waterproof housing, 22 mm x 208 mm (7/8″ x 8.2″).
A baked-on coating using polymerization technology protects the body against corrosion, abrasion and high temperatures. Double o-ring seals protect against leaks. The conductivity sensor is a 4-electrode platinum sensor, with autoranging capabilities. The minimal-maintenance, sealed Levelogger 6 LTC is simple to clean and calibrate, even in the field.
Features:
- Twice the previous PC interface download speed: using the Mk3 USB-C PC Interface Cable.
- Enhanced electronics: increased stability, sensitivity, and accuracy across temperature ranges
- Large memory: 100,000 sets of data, with dedicated backup memory for 15,000 sets
- Superior protection in harsh conditions: baked-on coating using polymerization, double o-ring seals
- Improved time tracking: stores time stamps, supports multiple time zone displays
Applications:
- Salt water intrusion and soil salination monitoring
- Plume remediation monitoring and studies
- Leachate monitoring at landfills, mine tailings, waste disposal storage sites, and more
- Agricultural and stormwater runoff monitoring
- Create a historical database for potable water supply monitoring
- Tracer tests
| Level Sensor: | Piezoresistive Silicon with Hastelloy Sensor |
|---|---|
| Ranges: | 5, 10, 20, 30, 100, and 200 m |
| Accuracy: | ±0.05% FS |
| Resolution: | 0.001% FS to 0.0006% FS |
| Over-pressurization: | 2-times over-pressure without permanent damage |
| Units of Measure: | cm, m, ft, psi, kPa, bar (°C, °F) |
| Normalization: | Automatic Temperature Compensation |
| Temp Comp. Range: | 0°C to 50°C |
| Temperature Sensor: | Platinum Resistance Temperature Detector (RTD) |
| Accuracy: | ±0.05°C |
| Resolution: | 0.003°C |
| Conductivity Sensor: | 4-Electrode Platinum |
| Full Range: | 0 – 100,000 μS/cm |
| Calibrated Range: | 50 – 80,000 μS/cm |
| Accuracy: | ±1%: 5,000 μS/cm – 80,000 μS/cm; greater of ±2% or 15 μS/cm: 50 μS/cm – 5,000 μS/cm |
| Resolution: | 0.1 μS/cm |
| Temp Comp. Range: | 0°C – 50°C |
| Normalization: | Specific Conductance @ 25°C |
| Battery Life: | 8 Years (1 reading every 5 minutes) |
| Clock Accuracy (typical): | ±1 minute/year (-20°C to 80°C) |
| Operating Temperature: | -20°C to 80°C |
| Maximum Readings: | 100,000 sets of readings |
| Dedicated Backup Memory: | 15,000 sets of most recent readings |
| Memory: | Slate or Continuous |
| Communication: | Optical high-speed: 9600, 57600 bps with USB Desktop/Field Reader; 19.2k with Mk3 USB-C PC Interface Cable |
| Size: | 22 mm x 208 mm (7/8″ x 8.2″) |
| Weight: | 200 grams (7.06 oz) |
| Corrosion Resistance: | Baked-on coating using polymerization technology (inside and out) |
| Other Wetted Materials: | Delrin®, Viton®, 316L stainless steel, Hastelloy®, PFAS-free PTFE coating, platinum coated sensors |
| Sampling Mode: | Linear, Event & User-Selectable Schedule with Repeat & Pause Modes, Future Start, Future Stop, Real-Time View |
| Measurement Rates: | 2 seconds to 99 hours |
| Barometric Compensation: | Software Wizard and Barologger 6 |